TM 9-2320-303-24-1
UTILITY POWER RECEPTACLE REPLACEMENT - CONTINUED
0076 00
REMOVAL - CONTINUED
1.
Remove two screws (1), two wires (2), and two lockwashers (8) from rear of receptacle (4). Discard lockwashers.
2.
Remove cover (6) from receptacle (4).
NOTE
Note position of receptacle for installation.
3.
Drill through and remove two rivets (5), receptacle (4), and chain (7) from cab (3). Discard rivets.
INSTALLATION
NOTE
If receptacle has no gasket, use adhesive applied to mating surfaces of receptacle and cab.
1.
Install chain (7) and receptacle (4) to cab (3) with two new rivets (5).
2.
Install cover (6) on receptacle (4).
3.
Install two new lockwashers (8) and two wires (2) with two screws (1).
4.
Install cab liners (WP 0176 00).
2
1
3
4
5
8
7
6
END OF WORK PACKAGE