TM 9-2320-303-24-1
NATO SLAVE RECEPTACLE REPLACEMENT - CONTINUED
0075 00
REMOVAL - CONTINUED
NOTE
Perform steps 3 and 4 only if angle bracket is damaged.
3.
Remove batteries (WP 0094 00).
4.
Remove three nuts (12), washers (11), screws (9), and angle bracket (1) from battery box (10).
INSTALLATION
NOTE
Perform steps 1 and 2 only if angle bracket was removed.
1.
Install angle bracket (1) on battery box (10) with three screws (9), washers (11), and nuts (12).
2.
Install batteries (WP 0094 00).
3.
Install NATO slave receptacle (5) and cap (7) on angle bracket (1) with four screws (6), and new locknuts (8).
4.
Install two cables (2) on NATO slave receptacle (5) with two lockwashers (3) and screws (4).
9
10
8
4
3
1
2
5
6
3
4
7
2
6
11
12
402-234
END OF WORK PACKAGE