TM 9-2320-303-24-1
WATER PUMP BELT MAINTENANCE - CONTINUED
0053 00
INSTALLATION
NOTE
Do not force belt on with screwdriver.
Put idler belt (5) on over idler pulley (1), water pump pulley (7), and accessory drive (6).
ADJUSTMENT
1.
Adjust idler belt adjusting screw (2) until belt free-play is less than 1/2 inch.
1
2
3
4
5
7
6
402-208
2.
Tighten idler pulley locknut (2) to 50 lb-ft (68 Nm).
3.
Install and adjust fan belts (WP 0056 00).
4.
Install fan (WP 0046 00).
END OF WORK PACKAGE