WATER MANIFOLD MAINTENANCE - CONTINUED
0051 00
INSTALLATION - CONTINUED
11.
Connect deaeration line (4) and heater hose (2) into front manifold (26).
12.
Install and tighten air compressor line (7).
13.
Attach return hose (3), radiator hose (5) and hose (8) to front manifold (26) and tighten clamps.
14.
Install transfer tube (9) to front manifold (26) with capscrew (1).
4
3
5
2
6
7
13
14
17
12
8
18
19
9
15
31
20
1
14
16
21
28
30
11
25
25
10
27
30
25
29 24
23
28
22
27
RH SIDE
ENGINE
BLOCK
WATER
25
PUMP
24
26
24
15.
Install water temperature switch wire (TM 9-2815-225-34&P).
16.
Install fan clutch actuator (TM 9-2815-225-34&P).
17.
Install air cleaner assembly (WP 0032 00).
18.
Install turbo air inlet (WP 0034 00).
19.
Refill cooling system and check for leaks (TM 9-2320-303-10).
END OF WORK PACKAGE