REMOVAL
1.
Unscrew and remove two nuts (11) and washer (10).
2.
Remove two wires (9) from terminals (14). Tag wires for installation references.
3.
Unscrew and remove four screws (12) and washers (13).
4.
Remove coil assembly (8), shield (7), o-ring (6), spring washer (5), and valve (4). Discard shield and o-ring.
5.
Unscrew and remove two screws (1) and two washers (2 and 3).
6.
Remove valve (16) and gasket (15). Discard gasket.
INSTALLATION
1.
While holding gasket (15) and valve (16) in place, insert two screws (1) and washers (2 and 3). Tighten screws.
2.
While holding coil assembly (8), shield (7), o-ring (6), spring washer (5) and valve (4) in place, insert four screws (12)
and washers (13).
3.
Tighten four mounting screws (12) and washers (13).
4.
Attach two wires (9) to terminals (14).
5.
Install nuts (11) and washers (10) on terminals and tighten.
6.
Install left fender (WP 0184 00).