WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL
APPENDIX H -- INPUT/OUTPUT FUNCTIONS
These schematics show the intended use of the specified controls features which
have been validated in the configuration shown. Any miswiring or use of these
features which differs from that shown could result in damage to equipment or
WARNING!
property, personal injury, or loss of life. ALLISON TRANSMISSION IS NOT
LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING
OR UNINTENDED USE OF THESE FEATURES.
AI.
MILITARY AUXILIARY FUNCTION RANGE INHIBIT (STANDARD)
USES: Prevents inadvertent range selection when auxiliary equipment is operating.
VARIABLES TO SPECIFY: None
VOCATIONS: Military wheeled vehicles
If this function is turned "ON" in the shift calibration, the function MUST be
integrated into the vehicle wiring. If the function is available in the shift
WARNING!
calibration but will not be used in the vehicle, it MUST be turned "OFF" in the
calibration.
WIRE 155
OPTIONAL
MILITARY AUX.
CUSTOMER-FURNISHED
FUNCTION RANGE
VIW CONNECTOR(S)
INHIBIT (STD)
Switch is closed when
V-11
auxiliary equipment
V
is operating
WIRE 161
V-31
SIGNAL RETURN
ECU
S
V04883
Figure H8. Military Auxiliary Function Range Inhibit (Standard)
0021 00181
|