WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL
DIAGNOSTIC CODES
Table 52. WT Series Diagnostic Codes (Continued)
CHECK
Main
Sub-
TRANS
Inhibited Operation
Code
code
Description
Light
Description
Yes(5)
34
12
Factory calibration compatibility
DNS, SOL OFF (hydraulic default), DNA
(0011 00-77)
number wrong
Yes(5)
DNS, SOL OFF (hydraulic default), DNA
13
Factory calibration block checksum
14
Power off block checksum
No
Use previous location, or factory
calibration and reset adaptive, DNA
15
Diagnostic queue block checksum
No
Use previous location, or clear diagnostic
queue, DNA
16
Real time block checksum
Yes
DNS, SOL OFF (hydraulic default), DNA
Yes(5)
DNS, SOL OFF (hydraulic default), DNA
17
Customer modifiable constants
checksum
35
00
Power interruption (code set after
No
None (hydraulic default during
(0011 00-79)
power restored)
interruption)
16
Real time write interruption
Yes
DNS, SOL OFF (hydraulic default), DNA
Yes (2)
36
00
Hardware/software not compatible
DNS, SOL OFF (hydraulic default), DNA
(0011 00-80)
No(2)
Use TIDCAP cal
01
TID not compatible with hardware/
software
02
TID did not complete
No
Use TIDCAP cal, code 42 XX or 69 XX
may be logged
42
12
Short-to-battery, A solenoid circuit
Yes
DNS, SOL OFF, DNA
(0011 00-82) 13
Short-to-battery, B solenoid circuit
Yes
DNS, SOL OFF, DNA
14
Short-to-battery, C solenoid circuit
Yes
DNS, SOL OFF, DNA
15
Short-to-battery, D solenoid circuit
Yes
DNS, SOL OFF, DNA
16
Short-to-battery, E solenoid circuit
Yes
DNS, SOL OFF, DNA
21
Short-to-battery, F solenoid circuit
No
Lockup inhibited, DNA
22
Short-to-battery, G solenoid circuit
Yes
DNS, SOL OFF, DNA
23
Short-to-battery, H solenoid circuit
No
Differential lock inhibited (3070 only),
retarder inhibited
24
Short-to-battery, J solenoid circuit
No
Low and 1st inhibited
26
Short-to-battery, N solenoid circuit
No
Low and 1st inhibited, allow retarder
44
12
Short-to-ground, A solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
(0011 00-86)
13
Short-to-ground, B solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
14
Short-to-ground, C solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
15
Short-to-ground, D solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
16
Short-to-ground, E solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
21
Short-to-ground, F solenoid circuit
No
Lockup inhibited, DNA
22
Short-to-ground, G solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
0021 0038
|