TM 9-2320-303-24-1
ANTI-LOCK BRAKE SYSTEM TROUBLESHOOTING AND TESTING - CONTINUED
0019 00
DIAGNOSTICS - CONTINUED
If you do not receive eight flashes, there are still active faults that must be repaired before they can be cleared.
d.
Blink Code Diagnostic Procedures:
For the step-by-step blink code diagnostic procedure, see Table 3.
Table 3. Blink Code Diagnostic Procedure.
MODE
PROCEDURE
SYSTEM RESPONSE
ACTION
Diagnostic
Step 1.
The ABS warning lamp comes on No recognizable faults in the ABS.
Turn the ignition on.
momentarily then goes out, No action required.
indicating System Okay.
The ABS warning lamp does not Inspect the wiring. Inspect the
light, indicating possible wiring bulb. Make necessary repairs.
fault or burned out bulb.
The ABS warning lamp stays on, Continue with the blink code
indicating there is a fault, or faults, diagnostics. Go to the next step.
in the system.
Step 2. Press and hold the The ABS warning lamp begins Determine if the fault is active or
Blink Code Switch for one flashing two-digit blink codes(s). stored:
Active Fault: The lamp will
second, then release.
repeatedly display one code.
Stored Fault: The lamp will
display the code for each stored
fault then stop blinking. Faults will
be displayed one at a time.
Step 3. Count the flashes to First Digit: 1 to 8 flashes, Pause Turn the ignition off. Find the
(11/2 seconds). Second Digit: 1 to definition for the blink code on the
determine the blink code.
blink code chart.
6 flashes, Pause (4 seconds).
Step 4. Repair and record the Active Fault.
Make the necessary repairs. Repeat
faults.
the first three steps of this
procedure until System Okay Code
(1-1) received.
Stored Faults.
Record for future reference.
NOTE: The last fault code stored is
the first fault code displayed.
Clear
Step 5. Clear faults from the The ABS warning lamp flashes All faults are successfully cleared.
memory: Press and hold the eight times.
Turn the ignition off.
blink code switch for at least
three seconds, then release.
Eight flashes are not received.
Active faults still exist, repeat the
first four steps of this procedure.
0019 00-9
|