TM 9-2320-302-20-2
CTIS AIR TUBE REPLACEMENT (M916A3, M917A2) - CONTINUED
0217 00
REMOVAL - CONTINUED
1.
Remove nut (4) from fitting (1).
2.
Remove air tube (5) from fitting (1).
3.
Remove insert (2), ferrule (3), and nut (4) from air tube (5).
5
4
3
2
1
INSTALLATION
NOTE
Procedure is the same for all air tubes.
1.
Install nut (4), ferrule (3), and insert (2) on air tube (5).
CAUTION
Route air tubes so that tube does not bend to radius smaller than allowed in Nylon Tube Bend Radius Table.
If bent smaller than allowed, tube may kink causing loss of air pressure.
NOTE
Apply a thin coat of thread sealing compound on male threads of fittings.
2.
Install nut (4) on fitting (1).
Nylon Tube Bend Radius Table
Outside Diameter
Minimum Bend Radius
in.
(mm)
in.
(mm)
0.25
(6.40)
1.0
(25.0)
0.38
(9.50)
1.5
(38.0)
0.50
(13.00)
2.0
(51.0)
0.63
(17.00)
2.5
(64.00)
0.75
(19.00)
3.0
(76.0)
3.
Check operation of CTIS (TM 9-2320-302-10).
END OF WORK PACKAGE
0217 00-2
|