CTIS WHEEL VALVE AND HOSE REPLACEMENT, FRONT
(M916A3, M917A2) - CONTINUED
0213 00
INSTALLATION - CONTINUED
WARNING
Ensure that all air lines and fittings are clear of debris and excess pipe sealing compound does not enter
air lines or fittings. Failure to follow this warning could result in injury to personnel and damage to
equipment.
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesive or sealing compound contacts skin or clothing, wash immediately with soap and water.
NOTE
Apply thin coat of sealing compound to all male threads.
3.
Install wheel valve connector (13) on wheel valve (8).
4.
Connect one end of hose (14) to wheel valve connector (13).
5.
Connect opposite end of hose (14) to tire valve stem (15).
6.
Install wheel valve connector (5) on wheel valve (8).
7.
Install one end of hose (4) on wheel valve connector (5).
8.
Install hub air port elbow (2) with open elbow port perpendicular to outer edge of wheel on wheel hub air port (1).
NOTE
Ensure hose is not kinked after connecting to elbow. Rotate elbow, if necessary.
9.
Connect opposite end of hose (4) to hub air port elbow (2).
10.
Check operation of CTIS (TM 9-2320-302-10).
END OF WORK PACKAGE
0213 00-3/(-4 Blank)