TM 9-2320-302-20-2
CTIS PNEUMATIC CONTROL UNIT (PCU) MAINTENANCE (M916A3, M917A2) - CONTINUED
0211 00
ASSEMBLY - CONTINUED
6.
Install solenoid protector (28) on each solenoid (27).
7.
Install metal gasket (29) with printed side up on each solenoid protector (28).
8.
Install nut (30) with beveled edge down on each spool (26).
9.
Apply adhesive to threads on pressure transducer (4).
10.
Install pressure transducer (4) ensuring electrical connector lock is oriented outward. Torque to 16-20 lb-ft (22-27 Nm).
11.
Tuck solenoid wires next to solenoids (27) and away from relief valve (25) while positioning cover (22) on PCU (7).
12.
Install cover (22) and six screws (23). Torque to 40-45 lb-in (4-5 Nm).
13.
Lube preformed packings on cartridges (17) and install cartridges into PCU (7) in same order as removed.
14.
Install gasket (18) and mounting plate (19) with raised side against PCU (7) and secure with six screws (20). Torque
screws to 40-45 lb-in (4-5 Nm).
WARNING
Ensure that all air lines and fittings are clear of debris and excess pipe sealing compound does not enter
air lines or fittings. Failure to follow this warning could result in injury to personnel and damage to
equipment.
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesive or sealing compound contacts skin or clothing, wash immediately with soap and water.
7
17
18
19
20
0211 00-5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |