REAR GLADHAND REPLACEMENT (M915A3 OLD MODEL) - CONTINUED
0194 00
REMOVAL - CONTINUED
NOTE
It is not necessary to remove gladhand to replace gladhand seal.
2.
Remove connector (2), nut (3), lockwasher (4), and gladhand (9) from bracket (5). Discard lockwasher.
3.
Remove dummy coupling (7), chain (8), bulkhead fitting (10), and seal (6) from gladhand (9).
1
2
5
3
4
6
10
9
7
8
INSTALLATION
1.
Install seal (6), chain (8), and dummy coupling (7) on gladhand (9).
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesives or sealing compound contacts skin or clothing, wash immediately with soap and water.
Ensure all air lines and fittings are clear of debris and excess pipe sealing compound does not enter air
lines or fittings. Failure to follow this warning could result in injury to personnel or damage to equip-
ment.
2.
Lightly coat threads of bulkhead fitting (10) with pipe sealing compound. Install bulkhead fitting on gladhand (9).
0194 00-2