Click here to make tpub.com your Home Page

Page Title: Figure 20. Multiple Splices.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-302-20-2
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0151 00
SPLICING - CONTINUED
b.
To heat shrink wrap a splice:
(1)
Select correct diameter to allow a tight wrap when heated. Heat shrink wrap MUST be long enough to
overlap wire insulation about 1/4 in (6.4 mm) on both sides of splice.
(2)
Heat shrink wrap with a heat gun; do not concentrate heat in one location, but play heat over entire length
of shrink wrap until joint is complete.
5.
Splicing Multiple Broken Wires.
a.
Stagger position of each splice as illustrated (Figure 20).
b.
You MUST stagger positions to prevent a large bulge in harness and to prevent wires from chafing against each
other.
CORRECT METHOD
2.5 in (64 mm)
TAPE SPLICED
MINIMUM
WIRES TOGETHER
BETWEEN SPLICES
INCORRECT METHOD
(BUILDING CONDUIT)
Figure 20. Multiple Splices.
0151 00-22

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business