TM 9-2320-302-20-2
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0151 00
COMMERCIAL CONNECTOR REPAIR - CONTINUED
Table 5. Deutsch Connectors and Part Numbers.
DIAGNOSTIC CONNECTOR
Connector
P/N: 23513052
Terminal
P/N: 23513053
Protective Cap
P/N: 23413054
Plug
P/N: 23507136
ENGINEMINDER
Connector
P/N: 23512222
Terminal
P/N: 23507132
Plug
P/N: 23507136
MASTERMIND - POWER AND COMMUNICATION LINK
Connector
P/N: 23512221
Terminal
P/N: 23507132
Plug
P/N: 23507136
MASTERMIND - INPUTS AND OUTPUTS
Connector
P/N: 23512223
Terminal
P/N: 23507066
Plug
P/N: 23507136
b.
Installation.
(1)
Strip approximately 1/4 in (6.4 mm) of insulation from cable.
(2)
Remove lock clip, raise wire gage selector, and rotate knob to number matching gage wire being used.
(3)
Lower selection and insert lock clip.
(4)
Position contact so that the crimp barrel is 1/32 in (0.8 mm) above four indenters (Figure 14). Crimp cable.