TM 9-2320-302-20-2
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0151 00
COMMERCIAL CONNECTOR REPAIR - CONTINUED
REMOVAL
TOOL J35689
LOCKING
TANG
BOTTOM VIEW OF TERMINAL
Figure 6. Terminal Removal.
(2)
Depress locking tang of terminal to release from connector.
(3)
Push cable forward through terminal until complete crimp is exposed.
(4)
Cut cable immediately behind damaged terminal to repair.
(5)
Follow installation instructions for crimping terminal and inserting into connector.
3.
Weather Pack and Metri-Pack 280 Connectors.
a.
Connector Part Numbers.
(1)
Weather Pack and Metri-Pack 280 series connectors are "push-to-seat design". The terminal is crimped
onto each wire before it is inserted into the connector. A cable seal is crimped on each wire at the same
time the terminal is crimped onto the wire. Weather Pack connectors use a secondary lock on both male
and female connector bodies and the lock snaps into place over the cable seals after installation. Some
Metri-Pack connectors have secondary locks as well.
(2)
Weather Pack connectors and their associated part numbers are listed in Table 3.
(3)
Metri-Pack 280 connectors and their associated part numbers are listed in Table 4.