COLLISION WARNING SYSTEM (CWS) CENTRAL PROCESSING UNIT (CPU) WIRING
HARNESS REPLACEMENT (M915A3, M916A3) - CONTINUED
0141 00
INSTALLATION - CONTINUED
Install fuse panel cover (WP 0084 00).
10.
11.
Install access cover (18) with three screws (17).
18
17
NOTE
Use strip caulk to provide a moisture-proof seal.
12.
Position bulkhead connector (13) at hole in cab floor and secure with lockwasher (16) and nut (15).
13.
Connect CWS wiring harness connector (14) to bulkhead connector (13).
14
15,16
13
0141 00-9