OIL TEMPERATURE SENSOR REPLACEMENT - CONTINUED
0114 00
INSTALLATION
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesives
or sealing compound contacts skin or clothing, wash immediately with soap and water.
CAUTION
Ensure that fittings are clear of debris and excess pipe sealing compound does not enter fittings or lines.
Failure to follow this caution could result in damage to equipment.
1.
Lightly coat threads of oil temperature sensor (2) with pipe sealing compound. Install oil temperature sensor on engine
block (3).
2.
Connect engine wiring harness connector (1) to oil temperature sensor (2).
1
2
3
END OF WORK PACKAGE