TM 9-2320-302-20-2
UTILITY POWER RECEPTACLE REPLACEMENT - CONTINUED
0091 00
INSTALLATION
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive or
sealing compound contacts skin or clothing, wash immediately with soap and water.
1.
Lightly coat mating surfaces of receptacle (4) and cab with adhesive.
2.
Install receptacle (4) and chain (7) on cab with two new rivets (5).
3.
Install cover (6) on receptacle (4).
4.
Install four new lockwashers (3) and two wires (2) on receptacle (4) with two screws (1).
5.
Install cab liners (WP 0264 00).
2
1
3
4
5
6
3
7
END OF WORK PACKAGE