TM 9-2320-302-20-2
SPINDLE AND HOUSING REPLACEMENT - CONTINUED
0061 00
INSTALLATION
1.
Install pipe nipple (4) and coupling (5) on spindle housing (3).
NOTE
DO NOT fully tighten bolts.
2.
Install spindle housing (3) on fan mounting support (2) with four washers (8) and bolts (7).
3.
For M915A3 Old Model, loosely install adjuster bolt (1) on fan mounting support (2) and spindle housing (3).
4.
Install air hose connector (6) on coupling (5).
1
2
3
8
7
4
5
6
5.
Install fan clutch and drive pulley (WP 0056 00).
END OF WORK PACKAGE