TM 9-2320-302-20-2
WATER FILTER ELEMENT REPLACEMENT - CONTINUED
0057 00
INSTALLATION - CONTINUED
CAUTION
DO NOT use a filter wrench to tighten water filter element. Failure to follow this caution may result in dam-
age to water filter element.
3.
Tighten water filter element (3) an additional 2/3 turn.
4.
Open two shutoff valves (1 and 2).
5.
Check coolant level (TM 9-2320-302-10).
1
2
3
END OF WORK PACKAGE