TM 9-2320-302-20-2
COOLANT HOSES AND PIPES REPLACEMENT (M915A3 NEW MODEL,
M916A3, M917A2) - CONTINUED
0048 00
REMOVAL - CONTINUED
16.
At other end of pipe (43), loosen two clamps (47) and remove pipe and elbow hose (46) from bottom of water pump
(17).
17
43
47
46
INSTALLATION
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive or
sealing compound contacts skin or clothing, wash immediately with soap and water.
1.
Install elbow hose (46) and pipe (43) to bottom of water pump (17) with two clamps (47).
2.
At other end of pipe (43), install elbow hose (41) and pipe to lower-left side of radiator (1) with two clamps (42).
3.
Lightly coat threads of fitting (44) with pipe sealing compound and install fitting to pipe (43). Install hose (34) to fitting
with clamp (45).