TM 9-2320-302-20-2
COOLANT HOSES, PIPES, AND CLAMPS REPLACEMENT (M915A3 OLD MODEL) - CONTINUED
0047 00
INSTALLATION - CONTINUED
9.
Install pipe (20) and two hoses (17) on water pump (18) and thermostat housing (12) with four clamps (16).
10.
Light coat threads of water pump tube (19) with pipe sealing compound. Install water pump tube on water pump (18).
11.
Install hose (15) on water pump tube (19) and radiator (8) with two clamps (14).
12.
Lightly coat threads of elbow (13) with pipe sealing compound. Install elbow on thermostat housing (12).
13.
Install hose (7) on elbow (13) and radiator (8) with two clamps (9).
14.
Install four clamps (6) on hose (7) and radiator support rod (10) with two screws (4), four washers (5), and two new
locknuts (11).
15.
Install pipe (1) and two hoses (3) on radiator (8) and thermostat housing (12) with four clamps (2).
1
2
3
9
2
15
13
7
14
12
2
32
16
4
8
20
5
17
67
16
9
17
16
19
16
6
5
18
11
15
10
14
16.
Fill cooling system (WP 0046 00).
END OF WORK PACKAGE