TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
NOTE
For steps 2 thru 48, engine must be running and clutch depressed. Failure to do so will
cause erroneous results.
Step 2. Pull and release suspension lockout control switch (5).
If indicator light lights when control switch is pulled but goes
out when control switch is released, go to step 8.
If indicator light is not lit but pump motor is running, go to
step 14.
If indicator light is lit, pump motor is running, but lockout is
not engaged, go to step 17.
If indicator light is lit but pump motor is not running, go to
step 30.
If indicator light is not lit and pump motor is not running, go to
step 3.
3-237