TM
5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 43. Check for +24 VDC between wire 11 (50) and ground at cab floor
separation point (25).
If +24 VDC is not present, repair wiring 11 between
connector AB and cab floor separation point.
If +24 VDC is present, go to step 44.
Step 44. Check for +24 VDC between wire 11 (50) and ground at hydraulic switch
(51),
If +24 VDC is not present, repair wiring 11 between cab floor
separation point and hydraulic switch.
If +24 VDC is present, go to step 45.
Step 45. Check for +24 VDC between wire 4 (52) and ground at hydraulic switch
(51).
If +24 VDC is not present, replace hydraulic suspension lockout
pump (page 4-51 1).
If +24 VDC is present, go to step 46.
3-233
|