TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 6. Check for +24 VDC between wire 713 (10) and ground at control switch (5).
If +24 VDC is not present, replace control switch (5) by
removing wire 712 (8), wire 714 (9), wire 713 (10), knob (11),
nut (12), and control switch.
If +24 VDC is present, go to step 7.
If +24 VDC is not present, repair wiring 713 between control
switch and solenoid relay.
If +24 VDC is present, go to step 8.
Step 8. Check wire 03 (14) at solenoid relay (13) for continuity to ground.
If open to ground, repair wiring 03 between solenoid relay and
NATO slave receptacle.
If short to ground, go to step 9.
3-220
|