TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 8. Disconnect connector K (12) and check for +24 VDC between wire 444 (10)
and ground.
If +24 VDC is present, repair wiring 444 between connector K
and turn signal lever.
If +24 VDC is not present, reconnect connector K and go to
step 9.
Step 9. Check for +24 VDC between wire 443 (13) and ground at master light
switch (14).
If +24 VDC is present, repair wiring 443 between master light
switch and connector K.
I f + 2 4 VDC is not present, go to step 10.
Step 10. Disconnect connector M (15) and check for +24 VDC between wire 442 (1)
and ground.
If +24 VDC is present, repair wiring 442 between connector M
and master light switch.
If +24 VDC is not present, reconnect connector M and go to
step 11.
Step 11. Disconnect connector J (4) and check for +24 VDC between wire 442 (1)
and ground.
If +24 VDC is present, repair wiring 442 between
connector J
and connector M.
If +24 VDC is not present, repair wiring 442 between
connector J and brake light switch.
3-189
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |