TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 14. Check for +24 VDC between wire 444 (17) and ground at turn signal lever
(9).
If +24 VDC is present, replace turn signal lever (page 4-122).
If +24 VDC is not present, repair wiring 444 between
connector K and turn signal lever.