TM
5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
NOTE
If STE/ICE-R Cl Engine GO-NO GO Chain does not diagnose cause of problem, return to
this troubleshooting table.
Step 3. Perform STE/lCE-R Cl Engine GO-NO GO Chain test procedures in the DCA
diagnostic mode.
If malfunction is found, refer to List of Tasks (page iii) or
Alphabetical Index (page Index-1) and repair or replace
damaged or faulty components.
If malfunction is not found, go to step 4.
Step 4. Disconnect connector D (3) and check for +24 VDC between wire 11 (4)
and ground.
If +24 VDC is not present, repair wiring 11 between starter
and connector D.
If +24 VDC is present, reconnect connector D and go to step 5.
Step 5. Remove defrost vent (5), nut (6), and washer (7) and pull ignition switch (8)
out through opening in dashboard (9).
Step 6. Check for +24 VDC between wire 11 (4) and ground at ignition switch (8).
I f + 2 4 VDC is not present, repair wiring 11 between connector
D and ignition switch.
I f + 2 4 VDC is present, go to step 7.
Step 7. Check for +24 VDC between wire 12 (10) and ground at ignition switch (8).
If +24 VDC is not present, replace ignition switch (page 4-131).
If +24 VDC is present, go to step 8.
3-71
|