OIL ANALYSIS PROGRAM SAMPLING PROCEDURES
The engine oil sampling valve is located on the end of the oil filter located on the right side of the engine. When a
lubrication note specifies that an oil sample must be taken, use the following procedures:
A
Ensure that oil to be sampled is at its normal operating temperature (page 2-40).
B
Open valve (1) and pump approximately two ounces of oil into suitable container, by pumping plunger
(2). Discard this oil. This will remove waste impurities from oil filter.
C
Place sample bottle (TB 43-0210) under valve (1) and fill sample bottle to approximately 1/2 in. (1.3 cm)
below neck of bottle. Close valve (1) and check for leaks.
D
Send oil sample to AOAP laboratory.
Change 2
2-70.3