TM 5-2420-222-34 16-4. HYDRAULIC IMPACTOR MOTOR ASSEMBLY REPLACEMENT. This Task Covers: a. Removal c. Installation b. Cleaning and Inspection Initial Setup: Equipment Conditions: Materials/Parts: Hydraulic impactor lines and fittings removed (see Rags (Item 28, Appendix B) TM 5 2420-222-20). Dry cleaning solvent (Item 31, Appendix B) Two seals General Safety Instructions: Tools/Test Equipment Dry cleaning solvent is flammable and must not be used near open flame.  Use only in a well General mechanic's tool kit ventilated area.   a. REMOVAL 1. Remove four screws (1) from rock drill bit (4) and hydraulic impactor (8). 2. Remove seal (3), rock drill bit (4), retaining plate (5), and seal (6) from hydraulic impactor (8).  Discard seals. 3. If damaged, remove four bushings (2) and studs (7). TA701669 16-17