TM 5-2420-222-34
8-20.
REVERSER CLUTCH CONTROL
15.
Remove vent plug (62), preformed packing (63), spring
(64), and ball bearing (65) from valve body (1).
Discard preformed packing.
16.
If damaged, remove two seals (61).
17.
Remove spring pin (67) and remote levers (66 and 68)
from valve body (1). Discard spring pin.
c.
CLEANING AND INSPECTION
WARNING
Avoid contact with live steam. Live steam can burn skin, cause blindness, and
other serious Injury. Be sure to wear protective apron, gloves, and safety goggles
when using live steam.
1.
Using steam cleaner, clean outside, all holes and recesses, and foreign matter from inside control valve.
WARNING
Compressed air used for cleaning or drying purposes, or for clearing restrictions,
should never exceed 30 psi (207 kPa). Wear protective clothing (goggles/shield,
gloves, etc.) and use caution to avoid injury to personnel.
2.
Flush valve body with clean water. Dry thoroughly with compressed air.
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only In a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame
or excessive heat. The solvent's flash point is 100°F-138°F (38°C-59C). If you
become dizzy while using cleaning solvent, Immediately get fresh air and medical
help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
3.
Using dry cleaning solvent and clean rag, wipe all other metal parts clean. Dry with clean, dry rags.
TA701424
8-94
|