TM 5-2420-222-34 5-3. FUEL METERING PUMP HELICAL GEAR REPLACEMENT. This Task Covers: a. Removal c.    Installation b. Cleaning and Inspection Initial Setup: Equipment Conditions: Materials/Parts: Valve cover removed (see TM 5-2420-222-20). Rags (Item 28, Appendix B) Dry cleaning solvent (Item 31, Appendix B) One lockwasher Tools/Test Equipment: General mechanic's tool kit Field automotive shop set General Safety Instructions: Timing alinement tool Dry cleaning solvent is flammable and must not be used near open flame.  Use only in a well-ventilated References: area. TM 5-2420-222-10 a. REMOVAL NOTE Cylinders  are  numbered  from  one  to  four  starting  at  fan  end  of  engine assembly. No. 1 cylinder Is at top dead center (TDC) when both of Its valves are fully closed and hole in flywheel Is alined with timing hole in flywheel housing. 1. Remove pin (1) and cover (2) from flywheel housing (4). 2. Manually crank engine assembly until no.1 cylinder is at TDC (see TM 5-2420-222-10). 3. Insert pin (1) through timing hole in flywheel housing (4) until it seats in hole of flywheel (3). TA701329 5-15

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business