TM 5-2420-222-20-3
HYDRAULIC IMPACTOR LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
11.
Two hoses(1)
Male quick coupler
a.
Screw on and tighten using 1 1/8-inch
(2) and female quick
and 1 1/2-inch open-end wrenches.
coupler (3)
b.
Take off tags.
INSTALLATION
12.
Two adapters (4)
Two new packings (5)
Place in position.
13.
Impactor upper
Two adapters (4)
Screw in and tighten using 1-inch open-
housing (6)
with assembled
end wrench.
packings (5)
14.
Two adapters (4)
Two elbows (7)
Screw in and tighten to same relative
positions as noted during removal using
two 1 1/4-inch open-end wrenches.
15.
Two elbows (7)
Two hoses (1)
a.
Screw in and tighten using 1 1/8-inch
and 1 1/4-inch open-end wrenches.
b.
Take off tags.
TASK ENDS HERE
TA243639
2-1882
|