TM 5-2420-222-20-3
AIR CLEANER RESTRICTION INDICATOR
JAW DIRECT LINEAR VALVE (SERIAL NUMBERS 319995 THRU 342573 ONLY)
This task covers:
a.
Removal (page 2-1792)
c.
Inspection/Replacement (page 2-1793)
b.
Cleaning (page 2-1792)
d.
Installation (page 2-1794)
INITIAL SETUP
Tools
Personnel Required
Wrench, open-end, 7/16-inch
One
Materials/Parts
Equipment Condition
Rags, wiping (item 21, Appendix C)
Left side grille removed
Solvent, drycleaning
(TM 5-2420-222-10)
(item 28, Appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Connector (1)
Restriction
Unscrew and take off.
indicator (2)
2.
Air cleaner (3)
Connector (1)
Using 7/16-inch open-end wrench, un-
screw and take out.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
3.
Restriction
Using clean, dry rag, wipe clean.
indicator (2)
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors. Do not
use near open flame or excessive heat. The flashpoint is 100F to 138F (38 to 59C). If you become
dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
4.
Connector (1)
a.
Clean in drycleaning solvent.
b.
Using clean, dry rag, wipe dry.
2-1792
|