TM 5-2420-222-20-3
MANIFOLD BLOCK-TO-CROWD CYLINDER OIL LINES (SERIAL NUMBERS 319995 THRU 342573 ONLY) -
CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
19. Union adapter (1)
Hose (2)
a.
Place drain pan underneath.
b.
Using two 1-inch open-end wrenches,
unscrew and take out.
c.
Tag (page 2-137).
20. Manifold block (3)
Nut (4)
Using 7/8-inch and 1-inch open-end
and union adapter (1)
wrenches, loosen.
21. Manifold block (3)
Union adapter (1)
a.
Note relative position for proper
with assembled
placement during installation.
packing (5)
b.
Using 1-inch open-end wrench,
unscrew and take out.
c.
Plug manifold block (3) (page 2-137).
d.
Get rid of drained fluid (page 2-137).
22. Union adapter (1)
Packing (5)
a.
Using pocket knife, take out.
b.
Get rid of.
23. Boom (6)
Hose (2)
a.
Note routing for proper placement during
installation.
b.
Pull out.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
24.
All plastic and
a.
Using clean rags dampened in solution
rubber parts
of detergent and water, wipe clean.
b.
Rinse in clean water.
c.
Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors.
Do not use near open flame or excessive heat. The flashpoint is 100°F to 138°F (38° to 59°C). If
you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If
contact with eyes is made, wash your eyes with water and get medical aid immediately.
2-1584
|