TM 5-2420-222-20-3 PRESSURE CONTROL VALVE - CONTINUED ACTION LOCATION ITEM REMARKS ADJUSTMENT - CONTINUED NOTE Steps 78 thru 80 only apply to loader backhoes with Serial Numbers 319995 thru 342573. 78. Plug (1) Packing (2) a. If not replaced during assembly, using pocket knife, take off. b. Get rid of. c. Place new one in position. NOTE There may be one or several washers in plug. 79. Washers (3) a. If pressure reading noted in step 69 was more than 1800 psi (12,411 kPa), decrease number. b. If pressure reading noted in step 69 was less than 1700 psi (11,721 kPa), increase number. 80. Pressure housing Plug (1) with a. Screw in and tighten using 1-inch (4) and spring (5) assembled parts open-end wrench. b. Repeat steps 68 thru 80. WARNING Do   not   attempt   to   disconnect   hydraulic   lines   and   fittings   while   engine   is   running   or   before hydraulic system pressure has been released.  When engine is running, hydraulic system is under pressure.  Hydraulic system pressure should be 0 psi (0 kPa) before lines are disconnected.  A line or  fitting  disconnected  under  pressure  will  blow  off  with  a  lot  of  force  and  could  cause  serious injury to personnel. 81. Loader backhoe Hydraulic system Release pressure (page 2-1191). WARNING Be careful when draining hot fluids.  Wear gloves to protect your hands from hot parts and fluids or severe burns could result. 82. Front support (6) Hydraulic pump (7) a. Place drain pan underneath to catch draining fluid. b.  Disconnect multi-range pressure gage and tube and pipe fitting kit fittings. 2-1214

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business