TM 5-2420-222-20-3
MANIFOLD-TO-JAW CONTROL VALVE OIL LINES (SERIAL NUMBERS 235786 THRU 235999 ONLY) - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors.
Do not use near open flame or excessive heat. The flashpoint is 100°F to 138°F (38° to 59°C). If
you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If
contact with eyes is made, wash your eyes with water and get medical aid immediately.
13
All metal parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
137).
Replace defective parts as needed.
14
Hose (1 or 2)
Look for cracks, breaks, cuts, and tears.
15
All metal parts
Look for cracks and breaks.
INSTALLATION
NOTE
If return oil line is being installed, skip steps 16 thru 18.
16
Straight
New packing (4)
Place in position.
adapter (3)
17
Valve (5)
Straight adapter (3)
a. Unplug valve (5).
with assembled
b. Screw in and tighten using open-end
packing (4)
wrench.
18
Straight
Hose (1)
a. Take off tag.
adapter (3)
b. Screw on and tighten using open-end
wrench.
2-1460
|