| |
TM 5-2420-222-20-3
PRESSURE CONTROL VALVE.TO.MANIFOLD OIL LINE (SERIAL NUMBERS 235786 THRU 235999 ONLY) -
CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
8.
Hose (1)
a.
Using clean rags dampened in solution
of detergent and water, wipe clean.
b.
Rinse with clean water.
c.
Using clean, dry rags, wipe dry.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and
use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe
vapors. Do not use near open flame or excessive heat. The flashpoint is 100° F to 138° F (38° to
59° C). If you become dizzy while using cleaning solvent, get fresh air immediately and get
medical aid. If contact with eyes is made, wash your eyes with water and get medical aid
immediately.
9.
All metal parts
a.
Clean in dry cleaning solvent.
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
137).
Replace defective parts as needed.
10.
Hose (1)
Look for cracks, breaks, tears and cuts.
11.
All metal parts
Look for cracks and breaks.
12.
All threaded parts
Look for damaged threads.
INSTALLATION
13.
Union adapter (2)
New packing (3)
Place in position.
2-1402
|