TM 5-2420-222-20-3 HYDRAULIC OIL COOLER-TO-CLUTCH CONTROL VALVE OIL LINE - CONTINUED ACTION LOCATION ITEM REMARKS REMOVAL - CONTINUED 7. Two clamps (1) and Two screws (3), a. Using 1/2-inch, 1/2-inch drive socket, two brackets (2) lockwashers (4), ratchet handle, and 1/2-inch open- and nuts (5) end wrench, unscrew and take apart. b. Get rid of lockwashers (4). 8. Two brackets (2) Two clamps (1) Take off. and four oil lines (6 thru 9) 9. Two brackets (2), Two screws (12), and a Using 9/16-inch, 1/2-inch drive oil pan (10), and lockwashers (13) socket, 5-inch extension, and engine block (11) ratchet handle, unscrew and take out. b. Get rid of lockwashers (13). 10 Oil pan (10) Two brackets (2) Take off. DISASSEMBLY 11 Hose (14) Clamp (15) Using 1/4-inch flat-tip screwdriver, loosen. 12 Two clamps (15 Slide off. and 16) 13 Oil line (17) Hose (14) Pull off. CLEANING NOTE For more information on how to clean parts, go to General Maintenance Instructions (page 2-137). 14 All rubber parts a. Using clean rags dampened with solution of detergent and water, wipe clean. b. Rinse with clean water. c. Using clean, dry rags, wipe dry. WARNING Drycleaning solvent P-D-680 is toxic and flammable.  Wear protective goggles and gloves and use only in a well ventilated area.  Avoid contact with skin, eyes, and clothes and don’t breathe vapors. Do not use near open flame or excessive heat.  The flashpoint is 100°F to 138°F (380 to 59°C).  If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.  If contact with eyes is made, wash your eyes with water and get medical aid immediately. 2-1364

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business