TM 5-2420-222-20-3
JAW CONTROL (DIRECT LINEAR) VALVE LINKAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or excessive heat. The
flashpoint is 100°F to 138°F (38° to 59°C). If you become dizzy while using cleaning
solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
7. All metal parts
a.
Clean in drycleaning solvent.
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-137).
Replace defective parts as needed.
8.
All metal parts
Look for cracks, breaks, and abnormal bends.
INSTALLATION
9. Valve (1)
Link (2)
Place in position.
10. Valve (1) and
New cotter pin (3)
a.
Place in position.
link (2)
b.
Using long roundnose pliers, bend
ends back.
11. Bracket (4) and
Short pedal (5)
Place in position.
link (2)
12. Bracket (4) and
New cotter pin (6)
a.
Place in position.
short pedal (5)
b.
Using long roundnose pliers, bend ends back.
13. Bracket (4) and
Long pedal (5)
Place in position.
link (2)
14. Bracket (4) and
New cotter pin (8)
a.
Place in position.
long pedal (7)
b.
Using long roundnose pliers, bend ends back.