TM 5-2420-222-20-2
CIRCUIT BREAKERS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
NOTE
Steps 13 thru 16 only apply to loader backhoes with Serial Numbers 235786 thru 235999.
On loader backhoes with Serial Numbers 235786 thru 235999, warning light flasher lead terminal
connects to 20 ampere circuit breaker rear terminal.
13.
Warning light
Nut (3) and
a.
Using 3/8-inch box wrench, unscrew
flasher lead
lockwasher (4)
and take off.
terminal (1) and
b.
Get rid of lockwasher (4).
terminal (2)
14.
Terminal (2)
Warning light
a.
Tag (page 2-137).
and nut (5)
flasher lead
b.
Take off.
terminal (1)
15.
Terminal (2) and
Nut (5) and
a.
Using 3/8-inch box wrench, unscrew
terminal (6)
lockwasher (7)
and take off.
b.
Get rid of lockwasher (7).
16.
Terminal (2)
Terminal (6)
a.
Tag (page 2-137).
and nut (8)
b.
Take off.
17.
Terminal (9) and
Nut (8) and
a.
Using 3/8-inch box wrench, unscrew
terminal (2)
lockwasher (10)
and take off.
b.
Get rid of lockwasher (10).
18.
Terminal (2)
Terminal (9)
a.
Tag (page 2-137).
b.
Take off.
19.
20 ampere circuit
Two assembled
a.
Using 3/8-inch, 1/4-inch drive socket
breaker (11) and
washer nuts (13)
and screwdriver grip spin handle,
two weld screws (12)
unscrew and take off.
b.
Get rid of.
20.
Cowl support (14)
20 ampere circuit
Take off.
and two weld
breaker (11)
screw (12)
2-520
|