TM 5-2420-222-20-2
CIRCUIT BREAKERS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
5.
Terminal (1) and
Nut (3) and
a.
Using 3/8-inch box wrench, unscrew
terminal (2)
lockwasher (4)
and take off.
b.
Get rid of lockwasher (4).
6.
Terminal (2)
Terminal (1)
a.
Tag (page 2-137).
b.
Take off.
7.
40 ampere circuit
Two assembled
a.
Using 3/8-inch, 1/4-inch drive socket
breakers (5) and
washer nuts (7)
and screwdriver grip spin handle,
two weld screws (6)
unscrew and take off.
b.
Get rid of.
8.
Cowl support (8)
40 ampere circuit
Take off.
breaker (5)
NOTE
On loader backhoes with Serial Numbers 235786 thru 235999, cigar lighter lead terminal connects
to 20 ampere circuit breaker front terminal. On loader backhoes with Serial Numbers 319995 thru
342573, warning light flasher lead terminal connects to 20 ampere circuit breaker front terminal.
9.
Cigar lighter lead
Nut (12) and
a.
Using 3/8-inch box wrench, unscrew
terminal (9) or
lockwasher (13)
and take off.
warning lights
b.
Get rid of lockwasher (13).
flasher lead terminal
(10) and terminal (11)
10. Terminal (11)
Cigar lighter lead
a.
Tag (page 2-137).
and nut (14)
terminal (9) or
b.
Take off.
warning flasher lead
terminal (10)
11. Terminal (11) and
Nut (14) and
a.
Using 3/8-inch box wrench, unscrew
terminal (15)
lockwasher (16)
and take off.
b.
Get rid of lockwasher (16).
12. Terminal (10)
Terminal (15)
a.
Tag (page 2-137).
b.
Take off.
2-518
|