TM 5-2420-222-20-2
TIME TOTAL METER AND LEAD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REPAIR
NOTE
For more information on how to repair wiring, go to General Maintenance instructions (page 2-
137).
INSTALLATION
14. Cowl (1)
Time total
Put in place.
meter (2)
15. Time total
Three screws (3),
With help of assistant, screw in and
meter (2) and
washers (4), new
tighten using 3/16-inch flat-tip screw-
cowl (1)
lockwashers (5),
driver, 5/16-inch, 1/4-inch drive socket,
and nuts (6)
2-inch extension, and ratchet handle.
16. Meter
Connector (8)
a.
Push on.
terminal (7)
b.
Take off tag.
NOTE
Time total meters on loader backhoes with Serial Numbers 235786 thru 235999 are grounded
differently from those on Serial Numbers 319995 thru 342573.
Steps 17 and 18 only apply to loader backhoes with Serial Numbers 235786 thru 235999.
17. Cowl (1)
Lead (9)
Route into place as noted during removal.
18. Cowl support
Warning light
Install (page 2-657).
flasher and bracket
19. Meter
Connector (11 or 12)
a.
Push on.
terminal (10)
b.
Take off tag.
2-514
|