TM 5-2420-222-20-2
TIME TOTAL METER AND LEAD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Electrical parts solvent cleaning compound (trichlorotrifluoroethane) is flammable, and reacts
violently with aluminum, titanium, barium, lithium, samarium, and sodium potassium. Cleaning
compound fumes displace air and it may be carcinogenic. Boiling point is 114°F (460C). Do not
wear jewelry. Wear rubber gloves and use only in well ventilated area. Avoid contact with skin,
eyes, and clothes and do not breathe vapors. Do not use near open flame or excessive heat. If
you become dizzy while using cleaning compound, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
NOTE
Step 7 only applies to loader backhoes with Serial Numbers 235786 thru 235999.
7. Lead (1)
a.
Using rag dampened with solvent
cleaning compound, wipe clean.
b.
Dip connectors in solvent cleaning
compound.
c.
Using clean, dry rags, wipe dry.
8. Time total
a.
Using clean rag, dampened with solvent
meter (2)
cleaning compound, wipe clean.
b.
Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors.
Do not use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If
you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If
contact with eyes is made, wash your eyes with water and get medical aid immediately.
9. All attaching
a.
Clean in drycleaning solvent
hardware
b.
Using clean, dry rags, wipe dry.
2-512
|