TM 5-2420-222-20-2
RIGHT INNER PLATFORM RAMP - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Accelerator pedal
Two screws (4),
a.
Using two 7/16-inch open-end
(1), center platform
lockwashers (5),
wrenches, unscrew and take apart.
support (2), and
and nuts (6)
b.
Get rid of lockwashers (5).
ramp (3)
2.
Yoke (7) and
Cotter pin (9)
a.
Using long roundnose pliers, bend ends
pin (8)
straight and take out.
b.
Get rid of.
3.
Accelerator pedal
Pin (8)
Take out.
(1) and yoke (7)
4.
Ramp (3)
Pedal (1)
Take off.
5.
Center platform
Ramp (3)
Take off.
support (2)
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 100°F to 138°F (38° to 59°C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
6.
Ramp (3)
a.
Using clean rags dampened with dry-
cleaning solvent, wipe clean.
b.
Using clean, dry rags, wipe dry.
7.
All attaching
a.
Clean in drycleaning solvent.
hardware
b.
Using clean, dry rags, wipe dry.
2-1096
|