TM 5-2420-222-20-2
RIGHT OUTER PLATFORM RAMP - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
NOTE
Step 5 only applies to loader backhoes with Serial Numbers 319995 thru 342573.
WARNING
Water soluble cleaning compound solvent is flammable and fumes are toxic. Flashpoint is 220°F (104°C).
Boiling point is 212°F (100°C). Do not store in temperatures above 150°F (65°C) or below 35°F (2°C). Do
not use near open flame or excessive heat. Do not wear jewelry, wear rubber gloves and goggles, and
use only in well ventilated area.
Avoid contact with skin, eyes, and clothes, and don't breathe vapors. Avoid contact with acids, aluminium,
or zinc; chemical reaction may result. If you become dizzy while using cleaning compound solvent, get
fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes with water and
get medical aid immediately.
CAUTION
Do not remove ramp pad unless inspection shows need for replacement. Pad may be destroyed during
removal.
5.
Ramp (1)
Pad (2)
a.
Note position for proper placement
during installation.
b.
Using clean rags and cleaning com-
pound solvent, dissolve adhesive.
c.
Using putty knife under edge, pull up
corner.
d.
Wet with more cleaning compound
solvent and continue to pull off.
e.
Repeat steps b thru d above until com-
pletely removed.
f.
Using clean rag dampened with clean-
ing compound solvent, remove all
adhesive from ramp (1).
g.
Rinse ramp (1) and pad (2) with clean
water.
h.
Using clean, dry rags, wipe dry.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
2-1090
|