RIGHT PLATFORM - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY - CONTINUED
WARNING
Water soluble cleaning compound solvent is flammable and fumes are toxic. Flashpoint is 220°F (1040C).
Boiling point is 2120F (1000C). Do not store in temperatures above 150°F (650C) or below 35°F (20C). Do not
use near open flame or excessive heat. Do not wear jewelry, wear rubber gloves and goggles, and use only in
well ventilated area. Avoid contact with skin, eyes, and clothes, and don't breathe vapors. Avoid contact with
acids, aluminium, or zinc; chemical reaction may result. If you become dizzy while using cleaning compound
solvent, get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes with water
and get medical aid immediately.
CAUTION
Platform pads may be destroyed during removal. Do not remove platform pads unless inspection shows need for
replacement.
9. Platform (1)
Pad (2)
a.
Note position for proper placement
during installation.
b.
Using clean rags and cleaning com-
pound solvent, dissolve adhesive.
c.
Using putty knife under edge, pull
up corner.
d.
Wet with more cleaning compound
solvent and continue to pull off.
e.
Repeat steps b thru d above until
completely removed.
f.
Using clean rag dampened with clean-
ing compound solvent, remove all
adhesive from platform (1).
g.
Rinse platform (1) with clean water.
h.
Using clean, dry rags, wipe dry.
i.
Repeat step 9 for remaining pad.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
10.
Platform (1) and
a.
Using clean, dry rags and solution of
pad (2), if present
detergent and water, wipe clean.
b.
Using clean, dry rags, wipe dry.