TM 5-2420-222-20-2
LEFT OUTER PLATFORM RAMP - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
5.
Ramp (1) and assem-
a.
Using clean rags dampened with solu-
bled pads (2, 3, and 4)
tion of detergent and water wipe clean.
if present
b.
Rinse with clean water.
c.
Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe vapors. Do not use near open flame or
excessive heat. The flashpoint is 1000F to 138°F (380 to 590C). If you become dizzy while using cleaning solvent,
get fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
6.
All attaching
a.
Clean in drycleaning solvent.
hardware
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts which cannot be repaired.
7.
Ramp (1)
Look for cracks, breaks, and abnormal
bends.
8.
Pads (2, 3, and 4)
Look for cracks, tears, and crumbling.
if present
9.
All metal parts
Look for damaged threads.
REPAIR
10.
Ramp (1)
If threads are damaged, using screw
threading set, restore threads.
2-1076
|