TM 5-2420-222-20-2
HOOD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
11.
Hood (1) and vandal
Four drive
a.
Using 1-pound head ball-peen hammer
cover (2)
screws (3)
and 1/8-inch straight drive pin punch,
drive out.
b.
Get rid of.
12.
Hood (1)
Vandal cover (2)
Take off.
13.
Hood (1) and two
Two screws (5) and
a.
Using 9/16-inch, 3/8-inch drive sock-
reinforcement
lockwashers (6)
et and ratchet handle, unscrew and
plates (4)
take out.
b.
Get rid of lockwashers (6).
14.
Hood (1)
Two reinforcement
Take off.
plates (4)
WARNING
Water soluble cleaning compound solvent is flammable and fumes are toxic.
Flashpoint is 220°F (104°C). Boiling point is 212°F (100°C). Do not store in
temperatures above 150°F (65°C) or below 35°F (2°C). Do not use near open flame
or excessive heat. Do not wear jewelry, wear rubber gloves and goggles, and use
only in well ventilated area. Avoid contact with skin, eyes, and clothes, and don't
breathe vapors. Avoid contact with acids, aluminum, or zinc; chemical reaction
may result. If you become dizzy while using cleaning compound solvent, get
fresh air immediately and get medical aid. If contact with eyes is made, wash your
eyes with water and get medical aid immediately.
CAUTION
Do not remove packing strips unless inspection shows need for replacement.
Packing strips may be destroyed during removal.
NOTE
Hood is equipped with three packing strips. All three packing strips are removed
the same way. One is shown. Repeat step 15 as needed to remove remaining
packing strips.
15.
Hood (1)
Packing strip (7)
a.
Note position for proper placement
during installation.
b.
Using clean rags and cleaning com-
pound solvent, dissolve adhesive.
c.
Using putty knife under edge, pull
up corner.