TM 5-2420-222-20-2
TIE ROD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
14.
c.
Using 1/2 to 1 1/2-inch adjustable pipe
wrench, unscrew by turning counter-
clockwise and take out.
d.
Take tube (1) out of machinists vise.
15.
Left and right
Two lubrication
Using 7/16-inch open-end wrench,
tie rod end
fittings (9)
unscrew and take out.
sockets (6 and 7)
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
16.
Two dust covers (8)
a.
Using clean rags dampened in solution
of detergent and water, wipe clean.
b.
Rinse with clean water.
c.
Using clean, dry rags, wipe dry.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and dont breathe
vapors. Do not use near open flame or excessive heat. The flashpoint is 100°F to 1380F (380 to
590C). If you become dizzy while using cleaning solvent, get fresh air immediately and get
medical aid. If contact with eyes is made, wash your eyes with water and get medical aid
immediately.
17.
Tube (1)
a.
Using clean rags dampened in dry-
cleaning solvent, wipe clean.
b.
Using clean, dry rags, wipe dry.
TA243173
2-931
|